Usage

To use the WOT Shift feature, keep your foot fully on the gas and shift quickly using the clutch. Keep the gas fully depressed through the shift. The WOT Box will detect the clutch switch signal and briefly cut the ignition and fuel to enable an effortless shift.

To use the 2-Step feature, fully depress the clutch. Next, fully depress the gas. The engine will rev up and hold the RPM that you have set. Quickly release the clutch while leaving the gas fully depressed to launch the car.

Programming

The WOT Box version 2.1 and up comes preset for an automatic WOT Shift kill time. This means that the WOT Box will automatically adjust the kill time to your shift time, up to a maximum of 600 ms. If you would like manual control over the WOT Shift kill time, start the car and hold down the button on the module and wait for the LED to begin to blink. Using the chart below, find the number of blinks that corresponds to the kill time that you want to set. Setting 0 blinks will disable the WOT Shift feature and setting 1 blink will set the automatic kill time mode. When you have reached the number of blinks that match your desired setting, simply let go of the button. To confirm, the WOT Box will blink back out the setting you entered.

The WOT Box comes preset for a 2-step RPM of 4000. To set the 2-Step RPM, repeat the same procedure described above, but keep the clutch down during the entire operation. This will signify to the WOT Box that you want to set the 2-step RPM and not the WOT Shift kill time. Use the second chart provided below to match up the desired RPM with the number of blinks. Setting 0 blinks will disable the 2-Step feature.

Ignition Cut Time Chart - Set with the clutch UP

BlinksIgnition Cut (ms)BlinksIgnition Cut (ms)BlinksIgnition Cut (ms)BlinksIgnition Cut (ms)
0Disabled6
1251227518
425
1Auto (default)
7
150
13300
19
450
225
8
175
14325
20
475
350
9
20015350
21
500
475
10225
16
375
22
525
510011250
17
400
23
550

2-Step RPM Chart - Set with the clutch DOWN

BlinksRPMBlinksRPMBlinksRPMBlinksRPM
0Disabled6
4000 (default)
12520018
6400
130007
420013540019
6600
232008
440014560020
6800
334009
460015580021
7000
4360010480016
600022
7200
5380011500017
620023
7400